Proud to support Glaucoma UK for 2024.

Sales & Expert Advice: 0808 196 9382
Sherwin-Williams Floorcoating Resupen WB Clear
Sherwin-Williams Floorcoating Resupen WB Clear
Payment by Visa, Master Card, PayPal Pay in 3, Pay By Bank, BACS

Sherwin-Williams Floorcoating Resupen WB Clear

5 litres (2 Finishes)
£128.25 £148.50 save 13% £153.90 (inc VAT)
  • Clear, Water-Based Polyurethane Seal
  • 5L Containers
  • Matte or Satin Finish
  • Two Pack
  • UV Stable
  • Resistant to Chemicals, Abrasion, Hot Water & Skydrol
In Stock
Payment by Visa, Master Card, PayPal Pay in 3, Pay By Bank, BACS

Description

Sherwin-Williams Floorcoating Resupen WB Clear

Versatile & durable Finishing Sealant 

Resupen WB Clear is a clear UV stable polyurethane finish for application onto concrete, plaster and wood or as a seal coat on Sherwin-Williams wall and flooring systems.

Grades available:
Resupen WB Clear - Satin finish
Resupen WB Clear Matt - Matt finish

Advantages

  • Excellent chemical resistance
  • UV stable
  • Good abrasion and impact resistance
  • Hygienic and easy to clean
  • No VOC’s
  • Resistant to hot water
  • Skydrol resistant

Recommended Uses

  • As a seal coat for other Sherwin-Williams floor coatings and screeds
  • Laboratories
  • Food factory units
  • Prisons and police cells
  • Pharmaceutical areas
  • Medical and healthcare
  • Can be used on floors and walls

Preparation

New Concrete Floors:

New concrete must be clean, sound, dry and fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm2 is required.

Timber Floors:

Must be clean, sound, dry. Old clear varnish/topcoat must be removed/sanded prior to application, as it may affect the inter-coat adhesion with Resupen WB Clear.

Existing Concrete Floors:

Remove all dirt, oil, grease, old paints or any or other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing. Local repairs should be carried out using Resuscreed PA or Resuscreed 45.

Existing Floors (previously coated):

All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.
Where Resupen WB Clear is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.
Where surfaces are found to be porous a primer coat may be required to achieve a uniform sealed surface

Priming

Resupen WB Clear may be applied directly to concrete or as a seal coat or top coat to a resin floor system specified in our datasheets where a primer is not required. When applied direct to porous substrates the surface may require priming. Dry surfaces may be primed with Resuseal WB Clear or Resuprime ST.
Where the Relative Humidity of the substrate exceeds 75% Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203. The number of coats to be applied is chosen in accordance with the following table.

ERH% Required Coating Thickness
75-85 1coat of RESUPRIME MVT at 200 microns per coat
85-92 2coats of RESUPRIME MVT at 200 microns per coat
92-97 3coats of RESUPRIME MVT at 200 microns per coat

Application

The ambient temperatures of the area should not be allowed to fall below 10°c throughout application and curing. Surface temperature must be above 5°c.

Mixing: Pre-mix the base component to a uniform consistency then add the entire contents of the hardener to the base and mix by using a slow speed handheld powered mixer and mixing paddle for approximately two to three minutes to achieve a consistent mixture.
Note: Do not use a separate mixing bucket as it may affect the mixing ratio.
Apply the whole mixed paint by using a spreading rake, roller and brush to achieve the maximum coverage within the specified pot life time frame.

Do not add water to this product.
Slip resistance can be improved by lightly broadcasting anti-slip aggregates on the first coat (after primer) whilst still wet and back rolling, at a rate of 50/100 g/m2. When cured apply the second Resupen WB Clear coat to secure the aggregates.

Full product data sheets and safety data sheets are available on request.

Specification

Product: Resupen WB Clear
Finish: Satin or Matt
Recommended thickness range: 100-150 μm WFT per coat
Colour: Clear

Products required for this system
Primer: Dependant on applied system.
System: Dependant on applied system.
Finish Coat :
Resupen WB Clear (Satin)
Resupen WB Clear Matt (Matt)

APPLICATION INFORMATION at 20°c

Revised 09/2019—Issue 2 : REF : PEWB/CL 2016
System Thickness
(Recommended)
100-150 microns WFT 31-47 microns DFT
*The suggested thickness range is calculated based on average volume solid as a general recommendation for the specified condition and for each application it may vary.
Solids Content by Weight 35%
Pack Sizes 5 litres
Pack Make Up 1 x Base 1 x Hardener
Shelf Life 24 months (Base) 12 months (Hardener)
Storage Keep out of direct sunlight. Store in a dry place, between 15°C- 30°C.
Solids Content by Volume 31%
Coverage Rate
(Theoretical)
5 litres will cover 50m2
@ 100 microns wet film thickness.
* Coverage rate is calculated based on a sealed and smooth surface and may vary based on the substrate roughness and other conditions.
Pot Life Up to 60 minutes
* water based coatings may stay liquid for longer than specified pot life but it is recommended to use all mixed paint within the pot life time frame. Application after pot life may affect the cure properties such as gloss and adhesion.
Recoating Intervals 6-8 hours
Light Traffic 12-16 hours
Full Traffic 48 hours
Full Chemical Cure 7 days

Category Guide
FeRFA Category: 1 and 2

Technical Information
The following figures are obtained from laboratory tests and our experience with this product.
Slip Resistance Dry > 60
Method BS7976 pt1-3 2002
The slip resistance of a floor surface can vary as a result of the installation process, conditions at the time of application and subsequent traffic. Inappropriate cleaning or maintenance can adversely affect performance. For further advice on potential wet areas please consult Sherwin-Williams
Abrasion Resistance 78.7 mg loss per 1000 cycles
Method BS8204 /ASTM D4060
Temperature Resistance Tolerant of temperatures of up to 60°c
Excellent chemical Resistance

Reviews

You're reviewing:

"Sherwin-Williams Floorcoating Resupen WB Clear"

Related Products

Get the lowdown from our blog

Newsletter Icon

Sign up to our newsletter to receive special offers and new product updates