Resucoat™ HB Profile is a 2-pack high solids, high-build epoxy resin system for application as a non-slip floor coating for light to medium industrial use at a thickness of 200 microns. The coating will provide a textured gloss coloured finish incorporating an anti-slip aggregate which is dispersed within the material during mixing. Applied by roller and paintbrush the product is low odour producing a seamless, hard wearing, hygienic floor finish.
New concrete must be clean, sound, dry, fully
cured and surface laitance removed by vacuum enclosed shot
blasting or mechanical grinding, a minimum strength of 25N/mm2 is required.
Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Resuscreed PA.
All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.
Where Resucoat HB Profile is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.
Open and porous substrates may require priming with Resuseal WB, also Resuprime ST or Resucoat HB may be used as primer on the dry substrates only with less than 75% ERH reading.
Where the Relative Humidity of a substrate exceeds 75% ERH Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203. The number of coats to be applied is chosen in accordance with the following table.
ERH% Required Coating Thickness
75-85 1coat of RESUPRIME MVT at 200 microns per coat
85-92 2coats of RESUPRIME MVT at 200 microns per coat
92-97 3coats of RESUPRIME MVT at 200 microns per coat
The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.
Mixing: Pre-mix the coloured base component to a uniform consistency then mix the entire
Full product data sheets and safety data sheets are available on request.
Product: Resucoat HB Profile
Finish: Lightly textured gloss
Recommended thickness range: 200 to 250 microns WFT per coat
Colour: Available in a range of colours, please consult our technical sales team
Products required for this system
Primer : Resuseal WB, Resuprime ST or Resuprime MVT on damp surfaces, where required.
System: Resucoat™ HB Profile
Surface Seal: Not required
System Thickness
(Recommended)
200-250 microns WFT 154-192 microns DFT
*The suggested thickness range is calculated based on average volume solid as a general recommendation for the specified condition and for each application may vary.
Solids Content by Weight ~100%
Pack Sizes 5 kg and 15 kg
Pack Make Up 1 x Base 1 x Hardener 1 x Aggregate
Shelf Life 36 months (Base, hardener and aggregate)
Storage Keep out of direct sunlight. Store in a dry place, between 15°C- 30°C.
Application Information at 20°C
Coverage Rate
(Theoretical)
5 Kg. will cover 17m2
@ 200 microns wet film thickness.
*Coverage rate is calculated based on a sealed and smooth surface and may vary based on the substrate roughness and other conditions.
Pot Life 25-30 Minutes from mixing, based on 5kg pack size.
*The pot life may be shorter for larger pack sizes if the paint not used with in the pot life limit.
Note: All mixed paint must be used within the pot life time limit. if the paint left in the container after mixing and not used, it may release hazard fumes due to exothermic reaction.
Recoating Intervals 6 hours or once surface has lost tackiness
Light Traffic 12-16 hours
Full Traffic 24-36 hours
Full Chemical Cure 7-10 Days
contents of the base with the hardener. If a separate mixing bucket is being used mix thoroughly ensuring all contents of the base and hardener are removed from the buckets supplied. Mix using a slow speed electric mixer for 1-2 minutes and add the Resucoat HB Profile aggregate whilst mixing.
Continue to mix for a further 1-2 minutes to ensure the aggregate is fully dispersed.
The mixed unit should be applied immediately by roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks.
Category Guide
FeRFA Category : 3
Technical Information
Slip Resistance Dry > 50
Method BS7976 pt1-3 2002
Temperature Resistance Tolerant of temperatures up to 45oC
VOC 186 g/l Calculated per full mixed unit
Transform any local tennis club lawn to a Wimbledon-worthy professional court with our top tips and tricks.
Proper preparation of your field or turf will ensure precise and vibrant lines that will stand the test of time.
Sports line marking can be daunting, with specific dimensions that directly shape the playing style and inform the rules, getting
The worst-case scenario is to spend a small fortune on line marking paint and applicators just for the fresh